XHT-M08 · FIELD TEST INSTRUMENTS
Fiber Test Kit
Inspect, clean, certify and troubleshoot fiber links in ready-to-use kits.
2 kits · Tier 1 loss certification & Tier 2 OTDR troubleshooting · MOQ 1
A fiber test kit bundles the tools a technician needs in one carry set. The Basic kit covers the complete Tier 1 workflow — inspect, clean and measure end-to-end loss with a matched source and power meter, plus visible-light fault tracing. The Professional kit adds an OTDR, a display microscope with cleaning set and a fiber identifier for distance fault location, patch-panel fiber finding and acceptance handover.
Basic Fiber Test Kit XHT-M08-B1 · Tier 1 Loss Certification Kit
Core applications: FTTH turn-up and routine maintenance, SMB and edge data-room patching, and access-network loss acceptance. The kit covers the complete Tier 1 workflow — inspect and clean end-faces, certify end-to-end insertion loss against the link budget, and trace visible faults — for installers, contractors and maintenance teams on single-mode and short multimode links.
What's in the Kit
 |
Rugged field power meter XHT-M01-RF
Measures absolute power and, with the source, insertion loss across 850–1625 nm to ±0.2 dB; a silicone housing withstands 2 m drops and the high-power range reaches +26 dBm.
| Calibrated wavelengths | 850/980/1300/1310/1490/1550/1625 nm |
| Measurement range | −70~+6 dBm · high-power −50~+26 dBm |
| Accuracy / resolution | ±0.2 dB / 0.01 dB |
| Optical port | 2.5 mm universal, SC adapter |
| Power / LED | 3×AA · built-in LED light |
| Dimensions / temp. | 85×45×160 mm · −10~+60 °C |
| Protection | Silicone housing, drop-tested to 2 m, waterproof keys |
|
 |
Performance handheld light source XHT-M04-P
Launches a stable reference signal (≥−5 dBm; ±0.05 dB/15 min) at 1310/1550 (MM/MS/PON options) to pair with the meter for loss tests.
| Wavelength options | SM 1310/1550 · MM 850/1300 · MS · PON |
| Output power | ≥−5 dBm |
| Stability | ±0.05 dB/15 min · ±0.1 dB/8 h |
| Modulation | CW / 270 Hz / 1 kHz / 2 kHz |
| Optical connector | SC + 2.5 mm universal; 1.25 mm LC optional |
| Power / display | 3×AA · LCD |
| Dimensions / weight | 160×85×45 mm · 220 g |
|
 |
Pen-style visual fault locator XHT-M03-A
650 nm red-light pen (standard 10 mW) makes breaks, bends and bad splices glow at the fault point.
| Wavelength | 650 nm red laser |
| Output power | 5/10/15/20/30/50/60/70/80/100 mW (standard 10) |
| Mode | CW / flashing |
| Optical interface | 2.5 mm universal; 1.25 mm LC/MU optional |
| Power / housing | 2×AA · high-grade alloy pen |
| Dimensions | 26 (W) × 26 (D) × 175 (H) mm |
|
 |
Handheld inspection microscope XHT-M07-H
Direct-view 100/200/400× scope with an IR safety filter and 2.5/1.25 mm adapters for quick end-face contamination and scratch checks.
| Inspection type | Direct-view optical microscope |
| Magnification | 100× / 200× / 400× |
| Focusing | Mechanical focus wheel |
| Adapters | 2.5 mm (SC/ST/FC/E2000) & 1.25 mm (LC/MU); SMA 905 optional |
| Laser safety | Built-in IR laser safety filter |
| Power / dimensions | 3×AAA · Ø57×225 mm |
|
 |
One-click connector cleaner XHT-T07-01
Push-to-clean 2.5 mm and 1.25 mm connectors with dry anti-static microfiber, 800 cleanings per tip.
| Connector tips | 2.5 mm SC/ST/FC & 1.25 mm LC/MU |
| Cleaning capacity | 800 cleanings per tip |
| Cleaning method | Dry anti-static microfiber, push-to-clean |
|
 |
Connector cleaning cassette XHT-T12-01
Cleans SC/FC/ST/LC end-faces for >550 passes with an alcohol-free dry microfiber tape and a visible-remaining window; replacement tape available.
| Connectors | SC/FC/ST/LC · 2.5/1.25 mm |
| Cleaning capacity | >550 cleanings, 10.5 m tape |
| Features | Replacement tape, visible-remaining window |
| Method / size | Dry, alcohol-free anti-static microfiber · 125×80×35 mm |
|
 |
Oxford cloth tool carry bag XHT-M15-02
Heavy-duty wear-resistant Oxford cloth bag with two main compartments, front and back pockets, a carry handle and shoulder strap keeps all tools organized and portable.
| Dimensions | 25 (W) × 16 (D) × 18 (H) cm |
| Material | Thickened wear-resistant Oxford cloth |
| Compartments | 2 main compartments + 1 front + 1 back pocket |
| Carry | Handle & shoulder strap |
|
Professional Fiber Test Kit XHT-M08-P1 · OTDR Troubleshooting Kit
Core applications: OTDR-based troubleshooting and acceptance of FTTH, access, enterprise and edge fiber links. Engineering and maintenance teams locate faults by distance on an event map, identify and trace live fibers at the patch panel without disconnecting them, and resolve the first-connector loss with a launch cable.
What's in the Kit
 |
Handheld OTDR XHT-M05-S4200 · in own carry case
D1 1310/1550 (26/24 dB) OTDR with a 1.5 m event dead zone and 0.1–125 km range maps every connector, splice, bend and break; one-key auto test and 1490/1577 PON power. The smartphone app enables remote control, data sharing and direct printing of test reports; the unit also integrates OPM, source, VFL and RJ45.
| OTDR module | D1 1310/1550, 26/24 dB (non-live) |
| Optional modules | F1 1550 · F2 1610 · F3 1625 · F4 1650, 24 dB (live) |
| Event / att. dead zone | 1.5 m / 8 m |
| Distance / pulse | 0.1–125 km · 5 ns–20 µs |
| Sampling / loss res. | ≥20,000 pts, ≤0.03 m · 0.01 dB |
| Optical port | SC/UPC or SC/APC |
| PON power | Simultaneous 1490/1577 nm readout |
| Auto test | One-key test with automatic analysis |
| Smartphone app | Bluetooth control, sharing, report printing |
| Display | 4.3″ color touch, auto rotate, sunlight mode, gesture zoom |
| Integrated functions | OTDR, event map, OPM, source, VFL, RJ45 |
| Power / dimensions | Li-ion · 86×33×144 mm |
|
 |
Display inspection & cleaning kit XHT-M07-DK · in own carry case
4.5″ HD 600× display scope captures JPG/AVI evidence at 1.0 µm resolution and ships with 2.5/1.25 mm cleaners and a cassette in a molded case.
| Display | 4.5″ HD screen, 1280×720 |
| Magnification / res. | 600× / 1.0 µm |
| Field of view | 0.316×0.285 µm |
| Sensor / media | 1/3″ 480 · JPG/AVI, TF card |
| Interface / controls | Type C/USB 2.0 · physical buttons |
| Battery | 4,000 mAh (2×2,000) |
| Temp. / humidity | Display −18~55 °C/30–85% RH · probe storage −18~35 °C |
| Size / weight | 158×80×24 mm · 0.30 kg |
| Connector coverage | UPC unmated SC/ST/FC/LC; UPC mated SC & LC; UPC+APC adds SC/APC |
| Cleaning in case | 2.5/1.25 mm pens · 500-clean cassette |
|
 |
Professional fiber identifier XHT-M11-02 · in zipper pouch
Clamps on a live fiber to show relative power and direction (800–1700 nm, InGaAs×2) with 4 interchangeable adapters, tone detection, 10 mW VFL and LED.
| Wavelength | 800–1700 nm |
| Detector | InGaAs ×2 |
| Display | Digital relative power & direction, sunshade |
| Adapters | 4 interchangeable: 250/900/2/3 mm, stored in case |
| Tone / sensitivity | 270/1k/2k · −35 dBm |
| Accuracy | CW −30 · modulated −25 |
| VFL / LED | 10 mW VFL · LED light |
| Dimensions | 244×82×40 mm |
|
 |
OTDR launch cable box XHT-M14-01
Sealed waterproof box with a known-length reference fiber eliminates the OTDR front-end dead zone so the first connector is measured; fiber, length and connectors to order.
| Box rating | Sealed waterproof / dustproof / impact-resistant |
| Box dimensions | 235×135×65 mm, carry clip |
| Configuration | Fiber type, length and connectors built to order |
|
Test Levels & Workflow
Field certification follows two industry-defined levels (ANSI/TIA-568; IEC 61280). End-face inspection and cleaning to IEC 61300-3-35 precede every test.
Tier 1 — Basic connectivity & loss
An OLTS — source plus power meter — measures end-to-end insertion loss and confirms continuity; a VFL traces visible faults. Tier 1 verifies the link is connected and within the loss budget — the Basic kit.
Tier 2 — OTDR event analysis
Tier 1 plus an OTDR with a launch cable characterizes every connector and splice — loss, reflectance and location — and pinpoints faults by distance; an identifier confirms the fiber and direction at the patch panel. Tier 2 yields traceable, event-level records for handover — the Professional kit.
Custom Configurations
Beyond the two standard kits, we configure kits to the exact job (MOQ 1, quoted on request). Our product portfolio covers the full range of field test equipment, with multiple models for different work conditions:
• Optical power meter
• PON power meter
• XGS-PON power meter
• Visual fault locator
• Optical light source
• Optical multimeter
• Pocket OTDR
• PON OTDR
• High-performance OTDR
• Single-fiber inspection microscope
• Multi-fiber inspection microscope
• OTDR launch cable · tool bag/case
Tell us your test scenario and we will build the kit from the appropriate models in our portfolio.
FAQ
Q1. Which kit do I need? Choose the Basic kit for FTTH turn-up and routine loss certification. Choose the Professional kit if you must locate faults by distance, find and trace fibers at the patch panel, or produce OTDR records for acceptance and handover.
Q2. What is the launch cable for? The OTDR has a front-end dead zone in which the first connector cannot be measured. The launch cable box provides a known-length reference fiber before the link, so the first connector's loss and the near-end events are visible.
Q3. Can the kits be configured for multimode or PON? Yes. The source/meter can be supplied in MM or single/multimode versions, and a PON OTDR or XGS-PON meter can be added for live PON.
Q4. MOQ and lead time? MOQ 1 for both kits. Reference lead time is 5 days for the Basic kit and 5–7 days for the Professional kit. Configuration changes, extra tools and bulk orders are arranged on request.
Ordering
• XHT-M08-B1 — Basic Fiber Test Kit (M01-RF + M04-P + M03-A + M07-H + T07-01 + T12-01 + M15-02). Lead time 5 days.
• XHT-M08-P1 — Professional Fiber Test Kit (S4200 OTDR + M07-DK scope kit + M11-02 + M14-01). Lead time 5–7 days.
• MOQ 1. Specify fiber type (SM/MM/MS), meter range, OTDR wavelength, identifier and launch-cable fiber/length/connectors when ordering. Orders are checked against the confirmed component list before packing; response within 24 h.
Related Products
• Handheld OTDR → XHT-M05 · PON OTDR → XHT-M06
• Optical power meter → XHT-M01 · XGS-PON power meter → XHT-M02
• Visual fault locator → XHT-M03 · Optical light source → XHT-M04
• Fiber inspection microscope → XHT-M07 · One-click cleaner → XHT-T07