Fiber Optic One-Click Cleaner
Time£º2026/10/28 21:02:24 Views£º201
Fiber Optic One-Click Cleaner

Fiber Optic One-Click Cleaner | XHT-T07 | Xihaitech
XHT-T07 · INSTALLATION TOOLS & CONSUMABLES
Fiber Optic One-Click Cleaner
Push-to-clean dry-cloth tools for single-fiber and multi-fiber connectors.
5 models · 2 classes · 2.5 / 1.25 mm ferrules plus 12/24-fiber MPO · 500–800 cleanings · MOQ 1
A single push removes dust, oil and contaminants from ferrule end faces using an optical-grade anti-static dry cloth, with the tape advancing automatically for a fresh surface every time. The range covers SC/ST/FC and LC/MU single-fiber ports, an angled tool for ONU ports, and 12/24-fiber MPO connectors for high-density data centers.
Model Lineup · 5 Cleaners in 2 Classes
Remove the cap, place the tip over the ferrule or into the adapter, and push until you hear a click: the 180° rotating cloth completes the sweep and the tape advances automatically. Each model cleans both unmated connectors (exposed ferrule) and mated connectors in adapters and bulkheads. Cleaning counts are stated per unit.
Class 1 · Single-Fiber Cleaners — SC/ST/FC & LC/MU XHT-T07-01 to 03
Classic one-click cleaner XHT-T07-01
The efficient, cost-effective choice for everyday single-fiber cleaning; offered in 2.5 mm for SC/ST/FC and 1.25 mm for LC/MU.
Classic fiber optic one-click cleaner, 2.5 mm SC/ST/FC and 1.25 mm LC/MU
Connectors2.5 mm ferrule: SC/ST/FC · 1.25 mm ferrule: LC/MU
Cleanings / body800 cleanings; standard body
Best fitGeneral FTTH and premises maintenance; cost-effective everyday use · reference lead about 3 days
Mini one-click cleaner XHT-T07-02
A compact 110 mm housing for tight, confined spaces and dense panels, in the same 2.5 mm and 1.25 mm ferrules.
Mini fiber optic one-click cleaner, 110 mm compact, 2.5 mm and 1.25 mm
Connectors2.5 mm ferrule: SC/ST/FC · 1.25 mm ferrule: LC/MU
Cleanings / body800 cleanings; compact 110 mm housing
Best fitConfined spaces, dense panels and crowded enclosures · reference lead about 3 days
ONU angled-head cleaner XHT-T07-03
The angled head reaches and cleans the SC connector inside an ONU, where a straight tool cannot align.
Angled-head ONU fiber optic cleaner for SC/ST/FC
ConnectorsSC/ST/FC (2.5 mm ferrule)
Cleanings / body600 cleanings; angled head
Best fitSC connector inside ONU/ONT terminals during activation · reference lead about 5 days
Class 2 · Multi-Fiber MPO Cleaners — 12/24-Fiber XHT-T07-04 & XHT-T07-05
MPO one-click cleaner, 500 XHT-T07-04
Cleans 12-fiber and 24-fiber MPO connectors in a single push, for both unmated and mated connectors.
MPO one-click cleaner for 12 and 24 fiber, solid housing, 500 cleanings
Connectors12-fiber and 24-fiber MPO
Cleanings / body500 cleanings; solid housing in blue, green or white
Best fitData-center MPO trunks and high-density patch panels · reference lead about 3 days
MPO one-click cleaner, 600 XHT-T07-05
Cleans 12-fiber and 24-fiber MPO connectors in a single push, with a longer service life in a transparent housing.
MPO one-click cleaner for 12 and 24 fiber, transparent housing, 600 cleanings
Connectors12-fiber and 24-fiber MPO
Cleanings / body600 cleanings; transparent housing in green, blue or orange
Best fitData-center MPO trunks and high-density links; longer service life · reference lead about 3 days
Cleaning Principles & Troubleshooting
Dust, oil and other contamination on a ferrule end face are common causes of insertion loss and unstable signals. For a reliable result:
• clean every ferrule before mating;
• seat the tip squarely and push fully until you hear the click;
• keep the protective cap on when the cleaner is not in use;
• repeat the push for heavy contamination.
Typical Applications
• Data-center 12/24-fiber MPO trunks, cassettes and high-density patch panels (MPO 500 / MPO 600).
• FTTH and ONU activation, including the angled SC port inside ONU/ONT terminals (ONU angled-head).
• ODF, cabinet and outside-plant maintenance, cleaning mated connectors in adapters (Classic / Mini).
• Routine single-fiber SC/ST/FC and LC/MU cleaning in premises and field work (Classic / Mini).
FAQ
Q1. Can it clean a mated connector inside an adapter? Yes. Clean exposed connectors directly, or insert the tip into the adapter to clean the mated connector in place.

Q2. Is solvent required? No. It is a dry-cleaning tool with anti-static cloth that advances automatically. Repeat the push for heavy contamination.

Q3. MOQ and lead time? All five models have an MOQ of 1. Reference lead is about 3 days for Classic, Mini and MPO models and about 5 days for the ONU angled model; housing colors and volume orders are arranged on request.
Ordering & Service
• Part number: XHT-T07-[01–05] — 01 Classic, 02 Mini, 03 ONU, 04 MPO 500, 05 MPO 600.
• Example: XHT-T07-03 = ONU angled-head cleaner; XHT-T07-05 = MPO 600 cleaner.
• MOQ 1; reference lead about 3 days (about 5 days for the ONU model); MPO housing colors, bulk and private-label orders arranged on request.
• Orders are checked against the confirmed model and cleaning count prior to packing.
• Response within 24 h; specification sheet and order confirmation on request.
Focus note: To recommend the correct cleaner, tell us the connector type (SC/ST/FC, LC/MU or MPO), the fiber count for MPO (12/24), the access situation (dense panel, confined space or ONU port), and the preferred cleaning count or housing color.
Related Products
• Connector cleaning cassettes (SC/LC/ST/FC & MPO, refills available) → XHT-T12
• Fiber optic cleaning master kit (cleaners, cassette & consumables) → XHT-T13
• Fiber Technician Field Kit (19-piece) → XHT-T06